Ruite Pump
Slurry Pump Manufacturer
+86 19933137467
Product Center
LOC:HOME > Other Pump > QJ oil-filled pump
Contact

Ruite Pump

TEL:+86 19933137467

E-mail:ruite@ruitepump.com

Skype:+86 19933137467

Wechat:+86 19933137467

Web:https://www.ruitepump.com

ADD:Shijiazhuang, Hebei, China

Model:

QJ oil-filled pump

catalogues: Other Pump
Capacity: 2-13m³/h
Head: 15-230m
Power: 0.75-7.5kw
Size: 40-50mm
Time: 2021-06-22
Pageviews:46

Description

QJ type oil-filled deep well pump is a water lifting device that directly connected a motor and a water pump to submerged into the water. It is suitable for extracting groundwater from deep wells, and can also be used for water lifting projects such as rivers, reservoirs, and canals, and submersible well pumps are mainly used Irrigation of farmland and water used by humans and animals in plateau and mountainous areas can also be used for water supply and drainage in cities, factories, railways, mines, and construction sites.

Product Features

1. The motor and the water pump are integrated and it can work when submerged in the water, safe and stable operation.

2. There are no special requirements for well pipes and raising water pipes(steel pipe wells, ash pipe wells, earth wells, etc.; steel pipes, rubber pipes and plastic pipes can be used as raising water pipes under pressure permitting).

3. It is very convenient to install, use and maintain. It occupies a small area and does not need to build a pump room.

4. Simple structure and saving some raw materials. Whether the submersible electric pumps are used under suitable conditions and managed properly have a direct relationship with the service life.

Working conditions

1. Power Requirements

(1) The rated frequency is 50Hz, and the motor rated voltage should be guaranteed to be a three-phase AC power supply of 380 + 5% volts (special order is required if the user voltage is 660 volts).

(2) The load power of the transformer should not exceed 75% of its capacity.

(3) When the transformer is far away from the well, it is considered that the voltage of the transmission line has dropped. For the motors power greater than 45KW, the distance between the transformer and the wellhead should not exceed 20 meters. When it is greater than 20 meters, the transmission line is required to be two grades larger than the distribution cable specification, and the line voltage drop is considered.

2. Water Quality Requirements

(1) General non-corrosive clean water.

(2) The sand content in the water is not more than 0.01% (mass ratio).

(3) The PH value is in the range of 6.5 to 8.5.

(4) The chloride ion content in the water is not more than 400 mg/L.

(5) The hydrogen sulfide content is not more than 1.5 mg/L.

(6) Water temperature is not higher than 20℃.

3. Well Pipe Requirements

The well is required to be upright and smooth. There is no any bulges or misalignment for well pipes, and the inner diameter of the well is not less than the corresponding frame number.